Custom Query (122 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (37 - 39 of 122)

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Ticket Resolution Summary Owner Reporter
#14 fixed Possible inconsistence in return messages from methods michaelhalloran michelpons

Reported by michelpons, 15 years ago.

Description

I am using as PME-PMC combination UniSim Design (PME) and Simulis Thermodynamics (PMC). In the log obtained with COLTT 1.08.03 enabled on the Simulis Thermodynamics Thermo System, I find the following: PropertyPackage <Anonymous> : GetComponentList returns :

Name CAS No Formula TBP MW Nitrogen 7727-37-9 N2 77.3565 28.0134 Argon 7440-37-1 Ar 80.3011 39.948 Oxygen 7782-44-7 O2 90.1792 31.9988

PropertyPackage <Anonymous> : Return from GetComponentList - Succeeded

It is a pattern that mentions \"Succeeded\" on the line corresponding to the return from a method.

But I find also:

PropertyPackage <Anonymous> : Call to GetComponentConstant requesting these constants :

molecularWeight

MaterialObject <Anonymous> : Call to get_ComponentIds

get_ComponentIds returns : 7727-37-9 7440-37-1 7782-44-7

MaterialObject <Anonymous> : Return from get_ComponentIds - Succeeded PropertyPackage <Anonymous> : GetComponentConstant returns

Compounds molecularWeight 7727-37-9 28.013400 7440-37-1 39.948000 7782-44-7 31.998800

The \"succeeded\" is not mentioned then.

#55 fixed PPM not queried on error returned michaelhalloran michelpons

Reported by michelpons, 14 years ago.

Description

The scenario is based on the one described for ticket #34 and is obtained when there is no PPDS license available. There is a complete process model developed in Aspen Hysys and making use of PPDS. Because the license is not there the PPM returns an error code 0x80040501 and this is logged in the log file. Aspen Hysys does not seem to pursue any further the matter. However I don't see any attempt from COLTT to query the error handling interfaces that should be present on the PPM object. I wonder why.

#43 fixed PME aborts in get_Reports Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

I am using a UO built by IFP within COFE 1.15. The UO is a 3-phase separator. When the UO is not logged, the calculation goes to its end but COFE displays warnings about properties not set. So I enabled COLTT on the UO and reran the case. With COLTT enabled on the UO, I can drop the UO in the flowsheet, I can connect the inlet port and the three outlet ports to streams, but COFE aborts when I double-click on the icon representing the UO. The Edit method of the UO is not implemented and normally the generic UO interface from COFE should have appeared so that I may give values to the UO parameters.

The attached COLTT log shows that the logging stops in get_Reports. I attach also the COFE document from where I start. The installer for the UO is too large to be attached and will be delivered through a file server.

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Note: See TracQuery for help on using queries.