Custom Query (122 matches)
Results (34 - 36 of 122)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#130 | duplicate | Repeated calls by COLTT on persistence interfaces | Michael Halloran | michelpons |
Description |
I am using COLTT 2.1 Build June 16, 2012 enabled on a TEA Thermo System and a COUSCOUS Mixer in PRO/II 9.1. I start from a case file where the TEA Thermo System and one of its PP has already been declared and two material streams have been defined. Then I drop the COUCOUS Mixer on the flowsheet, connect inlet ports and the outlet ports and then I run the simulation which ends up with no error. Parsing through the log file obtained, I am puzzled by the following sequence: COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Return from QueryInterface - Succeeded COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Return from QueryInterface - Succeeded COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Error returned from QueryInterface - 0x80004002 COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Return from QueryInterface - Succeeded COLTT <CO1> : Call to QueryInterface
COLTT <CO1> : Return from QueryInterface - Succeeded COLTT <CO1> : Call to IPersistStream.Save COLTT <CO1> : Return from IPersistStream.Save - Succeeded It seems there are repeated calls on the same interface by COLTT and that the failure to find this or that interface on the UO is not accounted for by COLTT which repeats on and on the same calls. This sequence seems to occur several times and since the overall logging takes quite longer than the simulation wothout any log, I was wondering if unnecessary calls were made by COLTT and if so could be discarded. |
|||
#53 | fixed | Recursive view of Call to get Option list in Viewer | michaelhalloran | michelpons |
Description |
The attached log file has been obtained with the 1.08.4 where DLLs have been superseded with the ones released on June 30, 2010. The scenario pertains to ticket #32. When looking at the log file with the Viewer and going at the last line displayed, expanding it, going to the last line, I get the same line as before. I can go on and go expanding the last line and apparently displaying the same sequence again. Looks odd to me. |
|||
#174 | fixed | ProSim Plus crashes with error interfaces automatic calls | Michael Halloran | michelpons |
Description |
I am using ProSim Plus 3.3.13.0 together with Aspen Properties v8.0. It is a simple flash but on a mixture containing ions. I am enabling COLTT on Aspen Properties Thermo System and I am running the flowsheet made of a single unit operation, a TP flash. When the box is ticked about error interfaces automatically called when errors are raised, ProSim Plus crashes. When I am simply enabling COLTT and no other options, the run goes to its end nicely. I am using COLTT 2.1 Build 280. My guess is that the description of the last error is a bit too long for COLTT to handle it, but it is just a guess. |