Ticket #130 (closed enhancement: duplicate)
Repeated calls by COLTT on persistence interfaces
Reported by: | michelpons | Owned by: | Michael Halloran |
---|---|---|---|
Priority: | minor | Milestone: | 2.2 |
Component: | COLoggers | Version: | Development |
Keywords: | Persistence | Cc: | michaelhalloran |
Description
I am using COLTT 2.1 Build June 16, 2012 enabled on a TEA Thermo System and a COUSCOUS Mixer in PRO/II 9.1. I start from a case file where the TEA Thermo System and one of its PP has already been declared and two material streams have been defined. Then I drop the COUCOUS Mixer on the flowsheet, connect inlet ports and the outlet ports and then I run the simulation which ends up with no error. Parsing through the log file obtained, I am puzzled by the following sequence:
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistPropertyBag
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStorage
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStreamInit
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStream
COLTT <CO1> : Return from QueryInterface - Succeeded
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistPropertyBag
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStorage
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStreamInit
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStream
COLTT <CO1> : Return from QueryInterface - Succeeded
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistPropertyBag
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStorage
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStreamInit
COLTT <CO1> : Error returned from QueryInterface - 0x80004002
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStream
COLTT <CO1> : Return from QueryInterface - Succeeded
COLTT <CO1> : Call to QueryInterface
Requested Interface : IPersistStream
COLTT <CO1> : Return from QueryInterface - Succeeded
COLTT <CO1> : Call to IPersistStream.Save
COLTT <CO1> : Return from IPersistStream.Save - Succeeded
It seems there are repeated calls on the same interface by COLTT and that the failure to find this or that interface on the UO is not accounted for by COLTT which repeats on and on the same calls. This sequence seems to occur several times and since the overall logging takes quite longer than the simulation wothout any log, I was wondering if unnecessary calls were made by COLTT and if so could be discarded.
Attachments
Change History
Changed 13 years ago by michelpons
- Attachment proii_061812_202144.log added
Log file obtained with COLTT 9.1 Build June 16, 2012