Ticket #79 (closed defect: fixed)
Log file does not load properly
Reported by: | michelpons | Owned by: | Michael Halloran |
---|---|---|---|
Priority: | major | Milestone: | 2.0 No dependency/Viewer/New installer |
Component: | Viewer | Version: | Development |
Keywords: | Cc: | michaelhalloran |
Description
I am using A+ v7.1 and a FORTRAN UO Mixer. While the run goes rather well (the UO is not found in mass balance by A+ though) with COLTT (May 30, 2011 build) enabled on the FORTRAN UO Mixer, the log file obtained does not load properly in the Viewer.
Attachments
Change History
Changed 14 years ago by michelpons
- Attachment apmain_060211_075106.log added
comment:1 Changed 14 years ago by michelpons
Michael, as per your message \"I can't explain this from the log. I can see that there is no Initialize call and no Terminate call. That seems odd. It could be a reference counting error so as an experiment I have modified the PPManager logger to add an additional reference count when getPropertyPackage returns an error. If there is a reference counting error this change should keep the PPManager alive a bit longer and then we might get more information in the log.\"
I have used the modified DLLs and I have got the attached log file.
Changed 14 years ago by michelpons
- Attachment apmain_060311_002754.log added
Log file obtained with DLLs modified as of June 2, 2011
Log file obtained with COLTT (May 30, 2011 build)