Ticket #79 (closed defect: fixed)

Opened 14 years ago

Last modified 13 years ago

Log file does not load properly

Reported by: michelpons Owned by: Michael Halloran
Priority: major Milestone: 2.0 No dependency/Viewer/New installer
Component: Viewer Version: Development
Keywords: Cc: michaelhalloran

Description

I am using A+ v7.1 and a FORTRAN UO Mixer. While the run goes rather well (the UO is not found in mass balance by A+ though) with COLTT (May 30, 2011 build) enabled on the FORTRAN UO Mixer, the log file obtained does not load properly in the Viewer.

Attachments

apmain_060211_075106.log (102.2 KB) - added by michelpons 14 years ago.
Log file obtained with COLTT (May 30, 2011 build)
apmain_060311_002754.log (102.2 KB) - added by michelpons 14 years ago.
Log file obtained with DLLs modified as of June 2, 2011

Change History

Changed 14 years ago by michelpons

Log file obtained with COLTT (May 30, 2011 build)

comment:1 Changed 14 years ago by michelpons

Michael, as per your message \"I can't explain this from the log. I can see that there is no Initialize call and no Terminate call. That seems odd. It could be a reference counting error so as an experiment I have modified the PPManager logger to add an additional reference count when getPropertyPackage returns an error. If there is a reference counting error this change should keep the PPManager alive a bit longer and then we might get more information in the log.\"
I have used the modified DLLs and I have got the attached log file.

Changed 14 years ago by michelpons

Log file obtained with DLLs modified as of June 2, 2011

comment:2 Changed 14 years ago by michaelhalloran

  • Status changed from new to closed
  • Resolution set to fixed

Fixed a syntax error in the log entry for IPersistStorage::IniNew.

Fix is committed and included in .msi file built after 5 June 2011

comment:3 Changed 13 years ago by michelpons

  • Milestone set to 1.08.05
Note: See TracTickets for help on using tickets.