Ticket #72 (new defect)

Opened 14 years ago

Last modified 9 years ago

Return list of GetCompoundConstant not showing in log

Reported by: michelpons Owned by: michaelhalloran
Priority: major Milestone:
Component: COLoggers Version: Development
Keywords: GetCompoundConstant Cc:

Description

I am using a COMThermo 1.1 PP in Aspen Hysys 7.2. At some point in the interaction between the two, I have this call:
PropertyPackage <Anonymous> : Call to GetCompoundConstant

GetCompoundConstant takes Input Arguments:

Property Compounds
criticalTemperature Ethanol

H2O

criticalPressure Ethanol

H2O

criticalVolume Ethanol

H2O

acentricFactor Ethanol

H2O

liquidDensityAt25C Ethanol

H2O

GetCompoundConstant returns:

Property Compounds ValueReturned
criticalTemperature Ethanol 17277.7

H2O 55397.2

PropertyPackage <Anonymous> : Return from GetCompoundConstant - Succeeded

I would have thought the entire list of properties to appear in the log. Now is it a defect in COLTT or elsewhere? I attach the complete log to this ticket.

Attachments

hysys_082410_203528.zip (7.1 KB) - added by michelpons 14 years ago.
Zipped log file obtained with COLTT built Aug 18, 2010

Change History

Changed 14 years ago by michelpons

Zipped log file obtained with COLTT built Aug 18, 2010

comment:1 Changed 13 years ago by michelpons

  • Milestone set to 2.02

comment:2 Changed 9 years ago by michelpons

Was something done about this issue? I am not capable to create a case with available PMCs/PMEs and COLT 2.2 that matches the situation described. Most PMEs seem to call on compound constant one property at a time. My recollection is that here several properties were queried at one. Did that create a problem?

Note: See TracTickets for help on using tickets.