Description
I am using a COMThermo 1.1 PP in Aspen Hysys 7.2. At some point in the interaction between the two, I have this call:
PropertyPackage <Anonymous> : Call to GetCompoundConstant
GetCompoundConstant takes Input Arguments:
Property Compounds
criticalTemperature Ethanol
H2O
criticalPressure Ethanol
H2O
criticalVolume Ethanol
H2O
acentricFactor Ethanol
H2O
liquidDensityAt25C Ethanol
H2O
GetCompoundConstant returns:
Property Compounds ValueReturned
criticalTemperature Ethanol 17277.7
H2O 55397.2
PropertyPackage <Anonymous> : Return from GetCompoundConstant - Succeeded
I would have thought the entire list of properties to appear in the log. Now is it a defect in COLTT or elsewhere? I attach the complete log to this ticket.
Attachments
Change History
Changed 14 years ago by michelpons
- Attachment hysys_082410_203528.zip added
comment:2 Changed 10 years ago by michelpons
Was something done about this issue? I am not capable to create a case with available PMCs/PMEs and COLT 2.2 that matches the situation described. Most PMEs seem to call on compound constant one property at a time. My recollection is that here several properties were queried at one. Did that create a problem?