Ticket #57 (closed defect: fixed)

Opened 14 years ago

Last modified 13 years ago

UO and PPM/PP logging not on same level in report

Reported by: michelpons Owned by: MichaelHalloran
Priority: major Milestone: 2.0 No dependency/Viewer/New installer
Component: COLoggers Version: Development
Keywords: Cc:

Description

The attached log has been obtained while enabling simultaneously logging on a UO PMC and on a PPM PMC. The PPM and the PP appears to be logged at the same level in the log through the Viewer while the UO operation calls are below the level of the PP. Normally the UO and the PP should be on the same level at least for the first calls.

Attachments

hysys_072610_212903.zip (31.3 KB) - added by anonymous 14 years ago.
Zipped log file obtained with 1.08.5 Build June 30, 2010
hysys_072610_212903 fixed.zip (30.3 KB) - added by michaelhalloran 14 years ago.
hysys_080110_225756.zip (29.7 KB) - added by michelpons 14 years ago.
Zipped log file obtained with COLTT update Aug 1 and viewed with Viewer updated Aug 1, 2010

Change History

Changed 14 years ago by anonymous

Zipped log file obtained with 1.08.5 Build June 30, 2010

Changed 14 years ago by michaelhalloran

comment:1 Changed 14 years ago by michaelhalloran

  • Status changed from new to closed
  • Resolution set to fixed

Viewer error caused by incorrect output from GetNumPhases. Corrected file uploaded so that level of PPM, PP and UO can be confirmed as correct.

comment:2 Changed 14 years ago by michelpons

I confirm that the issue has been fixed. I have rerun the scenario with the modifications of logger and viewer deliveredon Aug 1, 2010 and the PPM, PP and UO appear all at the same level when the log file is screened with the Viewer. I have attached the log file obtained.