Ticket #56 (closed defect: fixed)
Some problem reading a COLTT log file
Reported by: | michelpons | Owned by: | MichaelHalloran |
---|---|---|---|
Priority: | major | Milestone: | 2.0 No dependency/Viewer/New installer |
Component: | COLoggers | Version: | Development |
Keywords: | Cc: |
Description
The attached log file has been obtained by reloading a case in Aspen Hysys v7.2. The case involves a Property Package from MultiFlash Property Package Manager. There is a short error message when loading the file in the Viewer saying that some problem occurred when reading the file. The log file has been done with the COLTT build from June 30, 2010.
Attachments
Change History
Changed 14 years ago by anonymous
- Attachment hysys_072610_194448.log added
comment:1 Changed 14 years ago by michelpons
Another issue with this log file may be that a large part of the log file is not visible within the Viewer.
comment:2 Changed 14 years ago by michaelhalloran
- Status changed from new to closed
- Resolution set to fixed
Viewer error caused by incorrect output from GetNumPhases. Corrected file uploaded so that level of PPM, PP and UO can be confirmed as correct.
comment:3 Changed 14 years ago by michelpons
I confirm that the defect is resolved. I have rerun the scenario involving MultiFlash PPM and Aspen Hysys 7.2. There is no error message in the Viewer when opening the attached (Aug 1, 2010) log file in it.
Changed 14 years ago by michelpons
- Attachment hysys_080110_223527.zip added
Zipped log file obtained with Aug 1, 2010 modifications
Log file obtained with June 30, 2010 build