Ticket #56 (closed defect: fixed)

Opened 14 years ago

Last modified 13 years ago

Some problem reading a COLTT log file

Reported by: michelpons Owned by: MichaelHalloran
Priority: major Milestone: 2.0 No dependency/Viewer/New installer
Component: COLoggers Version: Development
Keywords: Cc:

Description

The attached log file has been obtained by reloading a case in Aspen Hysys v7.2. The case involves a Property Package from MultiFlash Property Package Manager. There is a short error message when loading the file in the Viewer saying that some problem occurred when reading the file. The log file has been done with the COLTT build from June 30, 2010.

Attachments

hysys_072610_194448.log (77.1 KB) - added by anonymous 14 years ago.
Log file obtained with June 30, 2010 build
hysys_072610_194448 fixed.zip (4.3 KB) - added by michaelhalloran 14 years ago.
hysys_080110_223527.zip (4.3 KB) - added by michelpons 14 years ago.
Zipped log file obtained with Aug 1, 2010 modifications

Change History

Changed 14 years ago by anonymous

Log file obtained with June 30, 2010 build

comment:1 Changed 14 years ago by michelpons

Another issue with this log file may be that a large part of the log file is not visible within the Viewer.

Changed 14 years ago by michaelhalloran

comment:2 Changed 14 years ago by michaelhalloran

  • Status changed from new to closed
  • Resolution set to fixed

Viewer error caused by incorrect output from GetNumPhases. Corrected file uploaded so that level of PPM, PP and UO can be confirmed as correct.

comment:3 Changed 14 years ago by michelpons

I confirm that the defect is resolved. I have rerun the scenario involving MultiFlash PPM and Aspen Hysys 7.2. There is no error message in the Viewer when opening the attached (Aug 1, 2010) log file in it.

Changed 14 years ago by michelpons

Zipped log file obtained with Aug 1, 2010 modifications

comment:4 Changed 13 years ago by michelpons

  • Milestone set to 1.08.05
Note: See TracTickets for help on using tickets.