Ticket #40 (closed enhancement: fixed)
Error log from ResolvePropertyPackage
Reported by: | michelpons | Owned by: | Michael Halloran |
---|---|---|---|
Priority: | minor | Milestone: | 2.2 |
Component: | COLoggers | Version: | 1.08.4 |
Keywords: | Cc: | michaelhalloran |
Description
While making a test of a Simulis Thermo System Property Package in UniSim Design, I made a mistake entering the IP address of the Simulis license server. Then I got a run involving a Simulis PP in UniSim Design to go wrong while the PP was logged with COLTT. The log shows:
LOG FORMAT
- Call on a given Object is indicated by 'Object<[Object Name]>: Call to [method name]'. *
- Input arguments and returned values(if any) are then indicated. *
- End of the call is indicated by 'Object<[Object Name]>: Return from [method name] - <Success Status>.' *
Log generated by C:
Program Files
Honeywell
UniSim Design R390
unisimdesign.exe
Using configuration from C:
Program Files
CAPE-OPEN
COLTT
CAPE-OPENLogs.ini
COLTT Version is 1.08.4
ClassFactory : Loading Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) implemented by
C:
PROGRA~1
Simulis
THRMST~3.DLL
ClassFactory : Created instance of Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) successfully
ClassFactory : Logging enabled for Thermo System Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1)
ThermoSystem <Anonymous> : Call to GetPropertyPackages
ThermoSystem <Anonymous> : GetPropertyPackages returns:
Bender-Kiwi-01-07-2009
Boite_froide_CO-1.0
ThermoSystem <Anonymous> : Return from GetPropertyPackages - Succeeded
ParameterCollection Parameter Collection Final Release...
Simulation Context <Anonymous> : Final Release
ThermoSystem <Anonymous> : Final Release
ClassFactory : Loading Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) implemented by
C:
PROGRA~1
Simulis
THRMST~3.DLL
ClassFactory : Created instance of Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) successfully
ClassFactory : Logging enabled for Thermo System Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1)
ThermoSystem <Anonymous> : Call to ResolvePropertyPackage
ThermoSystem <Anonymous> : PropertyPackage to be resolved : Bender-Kiwi-01-07-2009
Bender-Kiwi-01-07-2009 is a valid package name
ThermoSystem <Anonymous> : Error returned from ResolvePropertyPackage - 0x8007000e
ParameterCollection Parameter Collection Final Release...
Simulation Context <Anonymous> : Final Release
ThermoSystem <Anonymous> : Final Release
To me it seems that there is no attempt by COLTT to retrieve info on the error. For sure the error code is not a CAPE-OPEN one still...
Change History
comment:2 Changed 13 years ago by michaelhalloran
- Status changed from new to closed
- Resolution set to fixed
Fixed by #74 which is included in the 2.0 release. COLTT will generate a log for any error including non-CAPE-OPEN if the setting:
COLTT.AlwaysLogPMCErrors=true
is included in the CAPE-OPENLogs.ini file.