Ticket #151 (assigned defect)
Error methods logged within various calls
Reported by: | michelpons | Owned by: | michaelhalloran |
---|---|---|---|
Priority: | major | Milestone: | |
Component: | COLoggers | Version: | Development |
Keywords: | Cc: | michaelhalloran |
Description
I am using Aspen Plus v7.3.2 in which a TEA 1.0 Property Package named \"n-depropanizer\" is plugged in. A depropanizer column is simulated using Aspen Plus generic distillation column block. The run ends up in error with Aspen Plus reporting that calculations requested to the PP failed. Hence the logging with COLTT. I am puzzled by the error methods logged very repeatedly in the attached log, even in method calls that are said to succeed. The log file is not properly viewable in the Viewer.
Attachments
Change History
Changed 12 years ago by michelpons
- Attachment apmain_091412_185449.zip added
Changed 12 years ago by michelpons
- Attachment Depropanizer.zip added
Zipped apw file from Aspen Plus 7.3.2
comment:1 Changed 12 years ago by michaelhalloran
- Owner changed from Michael Halloran to michaelhalloran
- Status changed from new to assigned
The inability to use the Viewer on the log was caused by fix for 129 which assumed that MOs would always have a name - in Aspen Plus they don't. This is fixed by commit 250 and available in builds after 16th September. I will leave this open in case there are still issue with the sequence of error calls. In my logs from testing I see COLTT reporting the error that the Aspen Properties system is not initialised, and then Apmain repeats the same error interface calls. See attached log.
Zipped log file obtained with COLTT 2.1 Build 246