Ticket #9 (closed defect: wontfix)
Error 8004501 in ProSimPlus
Reported by: | michelpons | Owned by: | jasper |
---|---|---|---|
Priority: | minor | Milestone: | Phase II |
Component: | Demo PPM | Version: | 1.0 |
Keywords: | Cc: | w |
Description
When asking for an entropy/enthalpy calculation with the C6C8 PP of IdealThermoPPM in ProSimPlus?, at 1 atm, 300 Celsius and 60% mol C6,
ProSimPlus? displays:
ThermoPhysicalProperties? (0x80040501) OLE error 8004501
Attachments
Change History
Changed 8 years ago by michelpons
- Attachment prosimplus_082316_053010.log added
Changed 8 years ago by michelpons
- Attachment prosimplus_082316_053850.log added
Log of tun made at 100 Celsius
comment:1 Changed 8 years ago by michelpons
Need to check with ProSim? why description is not displayed.
comment:2 Changed 8 years ago by jasper
In the introduction to the Ideal Thermo Package: "The calculations are only allowed for sub-critical temperatures (see liquid phase description) so only compounds that are sub-critical at reference conditions are available.", and further down: "The liquid phase is ideal, with activity coefficients of unity. The system is intended to be used for T < Tcrit,i for all compounds, so that all vapor pressures are finite and positive. Calculations that violate this constraint result an error."
Log of tun at 300 Celsius leading to error