Ticket #9 (closed defect: wontfix)

Opened 8 years ago

Last modified 4 years ago

Error 8004501 in ProSimPlus

Reported by: michelpons Owned by: jasper
Priority: minor Milestone: Phase II
Component: Demo PPM Version: 1.0
Keywords: Cc: w

Description

When asking for an entropy/enthalpy calculation with the C6C8 PP of IdealThermoPPM in ProSimPlus?, at 1 atm, 300 Celsius and 60% mol C6,

ProSimPlus? displays:
ThermoPhysicalProperties? (0x80040501) OLE error 8004501

Attachments

prosimplus_082316_053010.log (60.0 KB) - added by michelpons 8 years ago.
Log of tun at 300 Celsius leading to error
prosimplus_082316_053850.log (78.8 KB) - added by michelpons 8 years ago.
Log of tun made at 100 Celsius

Change History

Changed 8 years ago by michelpons

Log of tun at 300 Celsius leading to error

Changed 8 years ago by michelpons

Log of tun made at 100 Celsius

comment:1 Changed 8 years ago by michelpons

Need to check with ProSim? why description is not displayed.

comment:2 Changed 8 years ago by jasper

In the introduction to the Ideal Thermo Package: "The calculations are only allowed for sub-critical temperatures (see liquid phase description) so only compounds that are sub-critical at reference conditions are available.", and further down: "The liquid phase is ideal, with activity coefficients of unity. The system is intended to be used for T < Tcrit,i for all compounds, so that all vapor pressures are finite and positive. Calculations that violate this constraint result an error."

comment:3 Changed 4 years ago by michelpons

  • Status changed from new to closed
  • Resolution set to wontfix

comment:4 Changed 4 years ago by michelpons

  • Milestone set to Phase II
Note: See TracTickets for help on using tickets.