IdealThermoPPM in Simulis Thermodynamics
Reported by: | michelpons | Owned by: | jasper |
---|---|---|---|
Priority: | major | Milestone: | Phase I Task 5: COBIA/COM Interop |
Component: | Demo PPM | Version: | 1.0 |
Keywords: | Cc: | wbarrett |
Description
I am able to select a PP from the IdealThermoPPM in Simulis Thermodynamics. Chose the C6C8 one from the list offered by Simulis. Immediately got a message box:
c:\users\me\documents\visual studio 2015\projects\cobia\cobia\cobia\client\cobia_dataadapters_h(1080):assert failed index out of range
OK it and then ProSimPlus? (Simulis Thermodynamics is launched from within ProSimPlus?) sends:
Variant or safe array is locked
Attachments
Change History
Changed 8 years ago by michelpons
- Attachment PPdescription.zip added
comment:1 Changed 8 years ago by michelpons
ProSimPlus? is at version 3.5.11.0, the most recent one (July 2016). I start ProSimPlus?, create a new project then access Simulis direct. I edit the default calculator, change it to CAPE-OPEN 1.1 PP, and ask to select a CAPE-OPEN PP. Simulis displays the list of PPs expected from the IdealThermoPPM.
After selection of the PP which leads to the above messages, any action tried on the calculator containing the PP leads to the above messages as well.
comment:2 Changed 8 years ago by jasper
- Status changed from new to closed
- Resolution set to fixed
A break was missing and has been inserted. Thank you for reporting.
Zipped screenshot showing PP description in Simulis