Ticket #66 (assigned defect)
Hysys crashes on opening file while logging PPM
Reported by: | michelpons | Owned by: | michelpons |
---|---|---|---|
Priority: | major | Milestone: | |
Component: | COLoggers | Version: | Development |
Keywords: | GetCompoundConstant | Cc: |
Description
For the purpose of checking an issue I have enabled logging on MultiFlash PPM and the I have opened up an Aspen Hysys case file where this PPM is used. Without COLTT enabled on the MultiFlash PPM, I have no problem opening the file even if Aspen Hysys flags some error messages regarding the fact that it will not support the solid phase defined in the Property Package. With COLTT enabled on MultiFlash PPM, Aspen Hysys crashes during the opening of the case file. The log file obtained (attached) seems to end suddenly within logging of GetCompoundConstant call. I have also logged the same system but developed in COFE, there is no problem but there is no call to GetCompoundConstant in COFE case. It may be that the large number of compounds leads to a situation that creates a problem.
Attachments
Change History
Changed 14 years ago by michelpons
- Attachment hysys_080510_185623.log added
Changed 14 years ago by michelpons
- Attachment cofe_080510_192608.log added
Log file obtained with COFE 2.1
Log file obtained with Aspen Hysys 7.2