Ticket #18 (closed defect: fixed)

Opened 15 years ago

Last modified 15 years ago

09-013 COULIS in PROII

Reported by: michelpons Owned by: Michael Halloran
Priority: major Milestone:
Component: COLoggers Version: 1.08.3
Keywords: Cc: technologyofficer@…

Description

De: Michel Pons [technologyofficer@…]
Envoyé: Wednesday, June 24, 2009 9:25 PM
À: 'Ahsan Akhtar'
Cc: 'Michael Halloran'
Objet: COLTT Issue 09-013 COULIS in PROII

Pièces jointes: Mylog240609.olg; proii_062409_211137_10802.log

Hi,

I have tried the following scenario : in PRO/II 8.3 I am creating a new case by inserting a CAPE-OPEN UO in the flowsheet (no thermodynamic model defined yet). PRO/II opens up a message box that lets one choose which CAPE-OPEN UO to select. I select COULIS from AmsterCHEM. With COLTT 1.08.02 enabled on COULIS, I get an immediate crash leading to the attached log file. With COLTT 1.07 I get also a crash but without any log file appearing in the destination folder.

Without COLTT enabled on COULIS, I am able to select which UO to log in COULIS, here GLCC. The attached olg file coming from COULIS shows that.

This issue has been numbered 09-013. let me know if you need me to install Visual Studio 2008 in the corresponding VM.

Best regards

Michel

Attachments

proii_062409_211137_10802.log (760 bytes) - added by michelpons 15 years ago.
Log file obtained with COLTT 1.08.02
Mylog240609.zip (12.3 KB) - added by michelpons 15 years ago.
Log file obtained with OATS
proii_102309_132849_v10803.log (806 bytes) - added by michelpons 15 years ago.
Log file obtained with COLTT 1.08.03 (Build Oct 19, 2009)

Change History

Changed 15 years ago by michelpons

Log file obtained with COLTT 1.08.02

Changed 15 years ago by michelpons

Log file obtained with OATS

comment:1 Changed 15 years ago by michelpons

I have tried the same combination with COLTT 1.08.03 (Build Oct 19, 2009). I have not seen any progress compared to COLTT 1.08.02 (see attached proii_102309_132849_v10803.log).

Changed 15 years ago by michelpons

Log file obtained with COLTT 1.08.03 (Build Oct 19, 2009)

comment:2 Changed 15 years ago by michaelhalloran

  • Cc technologyofficer@… added
  • Status changed from new to closed
  • Version changed from 1.08.2 to 1.08.3
  • Resolution set to fixed

Coulis is an out-of-process server. COLTT does not support logging these components, although it is possible to log the component running within Coulis. The same applies to the OATS thermo server. Fix is to disallow logging on out of process servers in the Logging Controller.