Ticket #114 (new defect)

Opened 13 years ago

Last modified 12 years ago

Error code changed with COLTT enabled on UO

Reported by: michelpons Owned by: Michael Halloran
Priority: major Milestone:
Component: COLoggers Version: Development
Keywords: Cc: michaelhalloran

Description

I am using PRO/II 9.1 and I am looking at a case file which has already been set up. The case involves the COUSCOUS UO Splitter and the CPP Thermo System example with a 3 compound PP. I am loading the case file and then I am launching the calculation. Without COLTT logged on the UO, I get the following message from PRO/II:
1 error(s), 0 warning(s), and 0 message(s) detected:

* error * Unit 1, 'co1', 'couscous mixer splitter mpo' - cape-open error 0x80040501: error during processing of cape-open unit.

while with COLTT enabled on the UO , I get:

1 error(s), 0 warning(s), and 0 message(s) detected:

* error * Unit 1, 'co1', 'couscous mixer splitter mpo' - cape-open error 0x80004005: error during processing of cape-open unit.

So there is a change from a ECapeUnknown error code to a Windows error code. While both messages do not tell what is going wrong, COLTT should not change the error code returned.

Attachments

proii_100311_113742.log (53.8 KB) - added by michelpons 13 years ago.
COLTT file obtained with 2.1 build Oct 1, 2011

Change History

Changed 13 years ago by michelpons

COLTT file obtained with 2.1 build Oct 1, 2011

comment:1 Changed 12 years ago by michelpons

  • Milestone changed from 2.1 to 2.2