Custom Query (122 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (109 - 111 of 122)

Ticket Resolution Summary Owner Reporter
#150 fixed Check if names of duplicated MOs are retrieved Michael Halloran michelpons

Reported by michelpons, 12 years ago.

Description

I am opening up in Aspen Plus v7.3.2 a case file that makes use of Aspen Plus embedded thermo and of the VB6 Mixer Splitter example used as a splitter. I run the case and analyze the log file obtained with COLTT 2.1 Build 246.

Within the Calculate call, there is a call to Duplicate the MO named as 1:

MaterialObject <1> : Call to Duplicate MaterialObject Duplicate returns clone: 013A43B0 MaterialObject <1> : Return from Duplicate - Succeeded

Once this is done I presume that most subsequent CalcProp and CalcEquilibrium calls are made on the duplicated MO. However the following is logged:

MaterialObject <1> : Call to CalcProp requesting:

Property Phase Calc enthalpy Liquid mixture

MaterialObject <1> : Return from CalcProp - Succeeded

I wonder if COLTT has really updated the name of the MO, or if the duplicated MO has the same component_Name as the original MO. I can't see any call to get_componentName on the ICapeIdentification interface carried by the duplicated MO. Would be necessary to know what is going on. If the duplicated MO is given the same name as the original MO by the PME, it may induce some recommendation to developers to avoid that situation.

#156 fixed Worflow of new Controller version Michael Halloran michelpons

Reported by michelpons, 11 years ago.

Description

Build 263 is used: when opening up Controller and selecting a given component, the \"Enable Logging\" box is appearing as non-ticked. The \"Call CAPE-OPEN error interfaces if errors are raised\" box and \"Log Reference counts\" box are ticked and greyed out. Then I tick the \"Enable Logging\" box. The \"Call CAPE-OPEN error interfaces if errors are raised\" box and \"Log Reference counts\" box remain ticked and are now ungreyed. Next I untick the \"Enable Logging\" box. The \"Call CAPE-OPEN error interfaces if errors are raised\" box and \"Log Reference counts\" box have then greyed out and unticked. I close the COLTT controller and then enters it again. When going to the same component as before, the \"Enable Logging\" box is unticked while The \"Call CAPE-OPEN error interfaces if errors are raised\" box and \"Log Reference counts\" box are ticked and greyed out.

I would think that ticking or unticking the \"Enable Logging\" box should not alter the two other boxes. Since by default these two boxes are ticked but greyed out, it means that they are partially independent from the \"Enable Logging\" box. Anyway they will be \"active\" only when a component is logged. Now I wonder if really the selection for these boxes is per component or rather is it for the entire set of components to be logged. I don't exactly how the implementation is done. If reference counting and error interface calls are not component dependent, the corresponding boxes should appear elsewhere than within a component detail.

#165 fixed Viewing log perturbed by special character Michael Halloran michelpons

Reported by michelpons, 11 years ago.

Description

With a log of a Simulis Thermodynamics PP in COFE, the file, when viewed within the Viewer, is not properly displayed. It seems to be related to the presence of special characters in name of the PPM.

Note: See TracQuery for help on using queries.