Ticket Resolution Summary Owner Reporter
#198 fixed ECapeThrmPropertyNotAvailable not considered as a CAPE-OPEN error michelpons michelpons

Reported by michelpons, 8 years ago.

Description

I have a PME returning 0x8004051a to a CalcsinglePhaseProp call: PropertyPackage <WaterEthanol> : Call to CalcSinglePhaseProp

CalcSinglePhaseProp takes input Arguments:

Property Phase POH Liquid

MaterialObject <1> : Call to GetPresentPhases

GetPresentPhases returns:

Phase Status Liquid CAPE_ATEQUILIBRIUM

MaterialObject <1> : Return from GetPresentPhases - Succeeded MaterialObject <1> : Call to GetTPFraction

GetTPFraction takes Input Argument:

The Phase: Liquid

GetTPFraction returns:

Phase Temperature Pressure Composition

Liquid 298.15 101325 0.9

0.1

MaterialObject <1> : Return from GetTPFraction - Succeeded COLTT <WaterEthanol> : Windows error code returned is: 0x8004051a - not known COLTT <WaterEthanol> : No error information available, call to GetErrorInfo returned: 0x1 PropertyPackage <WaterEthanol> : Error returned from CalcSinglePhaseProp - 0x8004051a PropertyPackage <WaterEthanol> : Call to get_description PropertyPackage <WaterEthanol> : Description: pO v CALUPP failed to calculate properties that may be caused by missing parameters or other reasons, please see history file. PropertyPackage <WaterEthanol> : Return from get_description – Succeeded

This is read by COLTT as a Windows error and not as a CAPE-OPEN error. It should be read as a CAPE-OPEN error.

#209 fixed System file missing for Controller Michael Halloran michelpons

Reported by michelpons, 7 years ago.

Description

in a Win 8.1 Enterprise N machine, after an apparently successful installation of first the x86 version of COLTT and then of the 64-bit version, launching the 64-bit controller leads to an error message: the mfc120.dll file is indicated as missing.

#27 wontfix Log enabled automatically on both Thermo System and PPM Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

I am using COLTT 1.08.3 Build Oct 27, 2009. The combination involves Simulis Thermodynamics Thermo System as PMC and UniSim Design R390.1 as PME. I enable logging on Simulis Thermodynamics Thermo System through COLTT controller. I run the simulation in UniSim Design R390.1 and get a log file (attached). When reopening COLTT controller to disable COLTT on Simulis Thermodynamics Thermo System, I observe that COLTT is also indicated as enabled on Simulis Thermodynamics Property Package Manager. I find this awkward even if we know that Simulis Thermodynamics is designed a bit differently from other thermo servers providing support for both 1.0 and 1.1.