Custom Query (122 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (70 - 72 of 122)

Ticket Resolution Summary Owner Reporter
#108 fixed Feature \"Clear all logs\" michaelhalloran michelpons

Reported by michelpons, 13 years ago.

Description

I am puzzled by the button \"Clear all logs\" on the main view of the COLTT controller. When using this button, none of the existing log files is suppressed. There is no secondary window popping up that would ask for confirmation of the action. I think such a button may have some sense but on the view for the Logs. Also it should work with a confirmation window.

#162 fixed Error when building COLTT Controller michaelhalloran michelpons

Reported by michelpons, 11 years ago.

Description

When building the COLTT controller debug solution from the code committed as 272, I get a fatal error at link time: LINK: fatal error LNK1104: impossible to open file \"log4cxx.lib\"

#40 fixed Error log from ResolvePropertyPackage Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

While making a test of a Simulis Thermo System Property Package in UniSim Design, I made a mistake entering the IP address of the Simulis license server. Then I got a run involving a Simulis PP in UniSim Design to go wrong while the PP was logged with COLTT. The log shows:

LOG FORMAT

  • Call on a given Object is indicated by 'Object<[Object Name]>: Call to [method name]'. *
  • Input arguments and returned values(if any) are then indicated. *
  • End of the call is indicated by 'Object<[Object Name]>: Return from [method name] - <Success Status>.' *

Log generated by C:
Program Files
Honeywell
UniSim Design R390
unisimdesign.exe Using configuration from C:
Program Files
CAPE-OPEN
COLTT
CAPE-OPENLogs.ini COLTT Version is 1.08.4

ClassFactory : Loading Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) implemented by C:
PROGRA~1
Simulis
THRMST~3.DLL ClassFactory : Created instance of Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) successfully ClassFactory : Logging enabled for Thermo System Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) ThermoSystem <Anonymous> : Call to GetPropertyPackages ThermoSystem <Anonymous> : GetPropertyPackages returns:

Bender-Kiwi-01-07-2009 Boite_froide_CO-1.0

ThermoSystem <Anonymous> : Return from GetPropertyPackages - Succeeded ParameterCollection Parameter Collection Final Release... Simulation Context <Anonymous> : Final Release ThermoSystem <Anonymous> : Final Release ClassFactory : Loading Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) implemented by C:
PROGRA~1
Simulis
THRMST~3.DLL ClassFactory : Created instance of Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) successfully ClassFactory : Logging enabled for Thermo System Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) ThermoSystem <Anonymous> : Call to ResolvePropertyPackage ThermoSystem <Anonymous> : PropertyPackage to be resolved : Bender-Kiwi-01-07-2009

Bender-Kiwi-01-07-2009 is a valid package name

ThermoSystem <Anonymous> : Error returned from ResolvePropertyPackage - 0x8007000e ParameterCollection Parameter Collection Final Release... Simulation Context <Anonymous> : Final Release ThermoSystem <Anonymous> : Final Release

To me it seems that there is no attempt by COLTT to retrieve info on the error. For sure the error code is not a CAPE-OPEN one still...