Custom Query (122 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (61 - 63 of 122)

Ticket Resolution Summary Owner Reporter
#171 fixed Incomplete log entries for GetTwoPhaseProp Michael Halloran michelpons

Reported by michelpons, 11 years ago.

Description

Still using the ChemSep UO with a TEA 1.1 PP and PRO/II 9.2.1.

Following a successful calculation of a two phase properties (surface tension) which sets a value on a MO, I see the ChemSep UO recovering (and apparently succeeding) the value calculated but here is the log:

MaterialObject <Anonymous> : Call to SetTwoPhaseProp MaterialObject SetTwoPhaseProp input arguments:

Property Phase Basis Value SurfaceTension Vapor (null) 0.0037951

MaterialObject <Anonymous> : Return from SetTwoPhaseProp - Succeeded PropertyPackage <n-depropropanizer> : Return from CalcTwoPhaseProp - Succeeded MaterialObject <Anonymous> : Return from CalcTwoPhaseProp - Succeeded MaterialObject <Anonymous> : Call to GetTwoPhaseProp

GetTwoPhaseProp takes Input Arguments:

Property Phase Basis

Liquid

Property Phase Basis ValueReturned

MaterialObject <Anonymous> : Return from GetTwoPhaseProp - Succeeded

Several pieces of information are missing since only one phase label appears. No value returned for example. The layout of the entry for that method should be GetTwoPhaseProp takes input Arguments:

Property Phase1 Phase2 Basis

GetTwoPhaseProp returns:

Property Phase1 Phase2 Basis ValueReturned

#65 fixed Incomplete view of log file in Viewer michaelhalloran michelpons

Reported by michelpons, 14 years ago.

Description

The attached log file, when seen through the Viewer, seems to stop on a Call to SetSinglePhaseProp on fugacity property for vapor phase with values of 49913.1 and 49613.4 while the log goes much further.

#67 worksforme Incomplete view of method calls michaelhalloran michelpons

Reported by michelpons, 14 years ago.

Description

The attached log file is obtained with the GLCC UO in Aspen Hysys 7.2. Using COLTT on the GLCC UO makes a number of error messages appear that do not exist without COLTT enabled on the GLCC UO (typically error setting cell color which is documented in a previous issue). When looking the log file with the Viewer, I can't locate the call to Calculate method which is in the log file.

Note: See TracQuery for help on using queries.