#154 fixed WaterPP and IdealThermoPPM do not have progID jasper jasper

Reported by jasper, 17 months ago.

Description

They both registered with only a version indepedendent progID.

In COM, progID and versionIndependentProgID are fully optional. However, it seems that one major PME does not like if the progID is not there and hides the PMC from the user.

#153 fixed COBIA objects register to COM with incomplete progID and versionIndependentProgID information jasper jasper

Reported by jasper, 17 months ago.

Description

ProgID/VersionIndependentProgID information is missing from the COM class key in the registry and from the progID registration level.

#152 fixed COBIA thermo providing components register for COM as 1.0 or 1.1 jasper jasper

Reported by jasper, 17 months ago.

Description

It depends on the order of CATIDs in the registration - the if statement that should be outside of the loop is inside of the loop.