id,summary,reporter,owner,description,type,status,priority,milestone,component,version,resolution,keywords,cc 28,08-136 COUSCOUS UO in PRO/II 8.2,michelpons,Michael Halloran,"I used COLTT 1.08.3 Build Oct 27, 2009 on a combination of PMC-PME that was used to document a defect in 2008 where it was impossible to get a log with COLTT 1.06. Logging is now possible with COLTT latest version. The calculation does not run properly in PRO/II. This may be related to the fact that it is PRO/II 8.2 that is used here. I get an error message from PRO/II saying: 2 error(s), 0 warning(s), and 0 message(s) detected: *** error *** Unit 1, 'co1' - the cape-open data file 'c:\\docume~1\\michel~1\\locals~1\\temp\\ssi82\\unconnected_co1.Dat' was not found. *** error *** Unit 1, 'co1' - not all material ports are connected. The COLTT log file (proii_103109_232827.log) is showing that disconnect calls on ports are raising exceptions: Port : Return from get_portType - Succeeded Port : Call to Disconnect Port : Error returned from Disconnect - 0x80040501 Port : Call to Disconnect Port : Error returned from Disconnect - 0x80040501 Port : Call to Disconnect Port : Error returned from Disconnect - 0x80040501 PRO/II seems to choose not to investigate further the exception since no attempt seems to be made to get information on the error. However I am puzzled by the fact that COLTT does not try either. I thought that, whatever the PME behaviour regarding error handling, COLTT logger was supposed to call ECapeUser and so on in order to get at least a better description of the error. It does not seem to happen there so the log is not sufficiently informative.",defect,closed,major,2.0 No dependency/Viewer/New installer,COLoggers,1.08.4,worksforme,,michaelhalloran