**********************************************LOG FORMAT********************************************** * Call on a given Object is indicated by 'Object<[Object Name]>: Call to [method name]'. * * Input arguments and returned values(if any) are then indicated. * * End of the call is indicated by 'Object<[Object Name]>: Return from [method name] - Error Status'. * ****************************************************************************************************** Log generated by C:\PROGRA~1\COCO\COFE.exe Using configuration from C:\Program Files\CAPE-OPEN\COLTT\CAPE-OPENLogs.ini ClassFactory : Loading COLaNMixer implemented by C:\Program Files\CAPE-OPEN 1.0 Unit\COLAN\COLANProject.dll ClassFactory : Created instance of COLaNMixer successfully ClassFactory : Logging enabled for Unit Operation COLaNMixer Unit : Call to ICapeKineticReactionContext not supported in COLTT Unit : Call to ICapeElectrolyteReactionContext not supported in COLTT Unit : Call to InitNew Unit : Return from InitNew - No Error Unit : Call to Initialize Unit : Return from Initialize - No Error Unit : Call to put_simulationContext Unit put_simulationContext takes input argument: 0x3dfeb8 Unit : Return from put_simulationContext - 0x80040509 Unit : Call to get_description Unit : Description: This method is not implemented. Unit : Return from get_description - No Error Unit : Call to ICapeIdentification.get_ComponentName Unit : Return from ICapeIdentification.get_ComponentName - No Error Unit : Call to put_ComponentName Unit put_ComponentName puts: COLaNMixer_1 Unit : Return from put_ComponentName - No Error Unit : Call to get_ports Unit : Return from get_ports - No Error PortCollection : Call to Count PortCollection : Count Is 3 PortCollection : Return from Count - No Error Unit : Call to get_ports Unit : Return from get_ports - No Error PortCollection : Call to Item requesting Item 1 PortCollection Item returns : 0x25c6ee0 PortCollection : Return from Item - No Error Port : Call to get_direction Port get_direction returns CAPE_INLET Port : Return from get_direction - No Error Port : Call to get_portType Port get_portType returns CAPE_MATERIAL Port : Return from get_portType - No Error Unit : Call to get_ports Unit : Return from get_ports - No Error PortCollection : Call to Item requesting Item 2 PortCollection Item returns : 0x25c85c0 PortCollection : Return from Item - No Error Port : Call to get_direction Port get_direction returns CAPE_INLET Port : Return from get_direction - No Error Port : Call to get_portType Port get_portType returns CAPE_MATERIAL Port : Return from get_portType - No Error Unit : Call to get_ports Unit : Return from get_ports - No Error PortCollection : Call to Item requesting Item 3 PortCollection Item returns : 0x25c9d18 PortCollection : Return from Item - No Error Port : Call to get_direction Port get_direction returns CAPE_OUTLET Port : Return from get_direction - No Error Port : Call to get_portType Port get_portType returns CAPE_MATERIAL Port : Return from get_portType - No Error Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to get_connectedObject Return from get_connectedObject with CAPE-OPEN error: Error Name : ECapeFailedInitialisationHR Error Code : 0x8004050f Object Name : Anonymous Interface : ICapeUnitPort Method : Get_ConnectedObject Description : There is not a connected object for the current port. Port : Return from get_connectedObject - 0x8004050f Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to get_connectedObject Return from get_connectedObject with CAPE-OPEN error: Error Name : ECapeFailedInitialisationHR Error Code : 0x8004050f Object Name : Anonymous Interface : ICapeUnitPort Method : Get_ConnectedObject Description : There is not a connected object for the current port. Port : Return from get_connectedObject - 0x8004050f Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to get_connectedObject Return from get_connectedObject with CAPE-OPEN error: Error Name : ECapeFailedInitialisationHR Error Code : 0x8004050f Object Name : Anonymous Interface : ICapeUnitPort Method : Get_ConnectedObject Description : There is not a connected object for the current port. Port : Return from get_connectedObject - 0x8004050f Unit : Call to ICapeIdentification.get_ComponentName Unit : Return from ICapeIdentification.get_ComponentName - No Error Unit : Call to Validate Starting validation state is CAPE_NOT_VALIDATED Unit : Return from Validate - No Error, isValid=false Validation state is now CAPE_INVALID message returned was: The number of inlet material connected ports must be > or = 2 The number of outlet material connected ports must be > or = 1 Unit : Call to get_ComponentDescription Unit get_ComponentDescription returns: COLaNMixer Unit : Return from get_ComponentDescription - No Error Unit : Call to Validate Starting validation state is CAPE_INVALID Unit : Return from Validate - No Error, isValid=false Validation state is now CAPE_INVALID message returned was: The number of inlet material connected ports must be > or = 2 The number of outlet material connected ports must be > or = 1 Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Port : Call to get_connectedObject Return from get_connectedObject with CAPE-OPEN error: Error Name : ECapeFailedInitialisationHR Error Code : 0x8004050f Object Name : Anonymous Interface : ICapeUnitPort Method : Get_ConnectedObject Description : There is not a connected object for the current port. Port : Return from get_connectedObject - 0x8004050f Port : Call to Disconnect Port : Return from Disconnect - No Error Port : Call to Connect Port : Return from Connect - No Error Unit : Call to Validate Starting validation state is CAPE_INVALID Unit : Return from Validate - No Error, isValid=false Validation state is now CAPE_INVALID message returned was: The number of inlet material connected ports must be > or = 2 The number of outlet material connected ports must be > or = 1 Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Unit : Call to Validate Starting validation state is CAPE_INVALID Unit : Return from Validate - No Error, isValid=false Validation state is now CAPE_INVALID message returned was: The number of inlet material connected ports must be > or = 2 The number of outlet material connected ports must be > or = 1 Port : Call to get_connectedObject Return from get_connectedObject with CAPE-OPEN error: Error Name : ECapeFailedInitialisationHR Error Code : 0x8004050f Object Name : Anonymous Interface : ICapeUnitPort Method : Get_ConnectedObject Description : There is not a connected object for the current port. Port : Return from get_connectedObject - 0x8004050f Port : Call to Disconnect Port : Return from Disconnect - No Error Port : Call to Connect Port : Return from Connect - No Error Unit : Call to Validate Starting validation state is CAPE_INVALID Unit : Return from Validate - No Error, isValid=false Validation state is now CAPE_INVALID message returned was: The number of outlet material connected ports must be > or = 1 Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Unit : Call to Validate Starting validation state is CAPE_INVALID Unit : Return from Validate - No Error, isValid=false Validation state is now CAPE_INVALID message returned was: The number of outlet material connected ports must be > or = 1 Port : Call to get_connectedObject Return from get_connectedObject with CAPE-OPEN error: Error Name : ECapeFailedInitialisationHR Error Code : 0x8004050f Object Name : Anonymous Interface : ICapeUnitPort Method : Get_ConnectedObject Description : There is not a connected object for the current port. Port : Return from get_connectedObject - 0x8004050f Port : Call to Disconnect Port : Return from Disconnect - No Error Port : Call to Connect Port : Return from Connect - No Error Unit : Call to Validate Starting validation state is CAPE_INVALID Unit : Return from Validate - No Error, isValid=true Validation state is now CAPE_VALID Port : Call to ICapeIdentification.get_ComponentName Port : Return from ICapeIdentification.get_ComponentName - No Error Unit : Call to Validate Starting validation state is CAPE_VALID Unit : Return from Validate - No Error, isValid=true Validation state is now CAPE_VALID Unit : Call to Validate Starting validation state is CAPE_VALID Unit : Return from Validate - No Error, isValid=true Validation state is now CAPE_VALID Unit : Call to Calculate MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoCompounds not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to ICapeThermoMaterial not supported by COLTT MaterialObject : Call to get_Name MaterialObject : Name: value not set MaterialObject : Return from get_Name - No Error MaterialObject : Call to get_code MaterialObject : Code: 0 MaterialObject : Return from get_code - No Error