Custom Query (122 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (25 - 27 of 122)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Ticket Resolution Summary Owner Reporter
#26 fixed Copyright notice ahsanakhtar michelpons

Reported by michelpons, 14 years ago.

Description

In the \"About\" window of COLTT controller, the copyright mentions 2005-2008 while it should be 2005-2009. I don't know how much it matters though. The same copyright appears in the \"Components\" view of COLTT controller and should be also updated(i.e. 2008 to 2009).

#27 wontfix Log enabled automatically on both Thermo System and PPM Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

I am using COLTT 1.08.3 Build Oct 27, 2009. The combination involves Simulis Thermodynamics Thermo System as PMC and UniSim Design R390.1 as PME. I enable logging on Simulis Thermodynamics Thermo System through COLTT controller. I run the simulation in UniSim Design R390.1 and get a log file (attached). When reopening COLTT controller to disable COLTT on Simulis Thermodynamics Thermo System, I observe that COLTT is also indicated as enabled on Simulis Thermodynamics Property Package Manager. I find this awkward even if we know that Simulis Thermodynamics is designed a bit differently from other thermo servers providing support for both 1.0 and 1.1.

#28 worksforme 08-136 COUSCOUS UO in PRO/II 8.2 Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

I used COLTT 1.08.3 Build Oct 27, 2009 on a combination of PMC-PME that was used to document a defect in 2008 where it was impossible to get a log with COLTT 1.06. Logging is now possible with COLTT latest version.

The calculation does not run properly in PRO/II. This may be related to the fact that it is PRO/II 8.2 that is used here. I get an error message from PRO/II saying:

2 error(s), 0 warning(s), and 0 message(s) detected:

* error * Unit 1, 'co1' - the cape-open data file 'c:
docume~1
michel~1
locals~1
temp
ssi82
unconnected_co1.Dat' was not found. * error * Unit 1, 'co1' - not all material ports are connected.

The COLTT log file (proii_103109_232827.log) is showing that disconnect calls on ports are raising exceptions:

Port <Outlet> : Return from get_portType - Succeeded Port <Inlet 1> : Call to Disconnect Port <Inlet 1> : Error returned from Disconnect - 0x80040501 Port <Inlet 2> : Call to Disconnect Port <Inlet 2> : Error returned from Disconnect - 0x80040501 Port <Outlet> : Call to Disconnect Port <Outlet> : Error returned from Disconnect - 0x80040501

PRO/II seems to choose not to investigate further the exception since no attempt seems to be made to get information on the error. However I am puzzled by the fact that COLTT does not try either. I thought that, whatever the PME behaviour regarding error handling, COLTT logger was supposed to call ECapeUser and so on in order to get at least a better description of the error. It does not seem to happen there so the log is not sufficiently informative.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Note: See TracQuery for help on using queries.