#27 wontfix Log enabled automatically on both Thermo System and PPM Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

I am using COLTT 1.08.3 Build Oct 27, 2009. The combination involves Simulis Thermodynamics Thermo System as PMC and UniSim Design R390.1 as PME. I enable logging on Simulis Thermodynamics Thermo System through COLTT controller. I run the simulation in UniSim Design R390.1 and get a log file (attached). When reopening COLTT controller to disable COLTT on Simulis Thermodynamics Thermo System, I observe that COLTT is also indicated as enabled on Simulis Thermodynamics Property Package Manager. I find this awkward even if we know that Simulis Thermodynamics is designed a bit differently from other thermo servers providing support for both 1.0 and 1.1.

#28 worksforme 08-136 COUSCOUS UO in PRO/II 8.2 Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

I used COLTT 1.08.3 Build Oct 27, 2009 on a combination of PMC-PME that was used to document a defect in 2008 where it was impossible to get a log with COLTT 1.06. Logging is now possible with COLTT latest version.

The calculation does not run properly in PRO/II. This may be related to the fact that it is PRO/II 8.2 that is used here. I get an error message from PRO/II saying:

2 error(s), 0 warning(s), and 0 message(s) detected:

* error * Unit 1, 'co1' - the cape-open data file 'c:
docume~1
michel~1
locals~1
temp
ssi82
unconnected_co1.Dat' was not found. * error * Unit 1, 'co1' - not all material ports are connected.

The COLTT log file (proii_103109_232827.log) is showing that disconnect calls on ports are raising exceptions:

Port <Outlet> : Return from get_portType - Succeeded Port <Inlet 1> : Call to Disconnect Port <Inlet 1> : Error returned from Disconnect - 0x80040501 Port <Inlet 2> : Call to Disconnect Port <Inlet 2> : Error returned from Disconnect - 0x80040501 Port <Outlet> : Call to Disconnect Port <Outlet> : Error returned from Disconnect - 0x80040501

PRO/II seems to choose not to investigate further the exception since no attempt seems to be made to get information on the error. However I am puzzled by the fact that COLTT does not try either. I thought that, whatever the PME behaviour regarding error handling, COLTT logger was supposed to call ECapeUser and so on in order to get at least a better description of the error. It does not seem to happen there so the log is not sufficiently informative.

#29 fixed Size of MSI ahsanakhtar michelpons

Reported by michelpons, 14 years ago.

Description

Size of the MSI file for COLTT 1.08.3 (Build Oct 27, 2009) is 22,178 Kbytes while it was only 4,646 Kbytes for the MSI of COLTT 1.07. Refactoring was not supposed to give way to such an increase in code size. So why such an increase?