Custom Query (122 matches)
Results (19 - 21 of 122)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#38 | fixed | get_ValStatus improperly logged | Michael Halloran | michelpons |
Description |
I am using the scenario used in Ticket#21. When analyzing the log obtained with COLTT 1.08.4 (proii_110609_112126), I see the following for the logging of a get_ValStatus call: Unit <CO1> : Call to get_ValStatus Unit <CO1> : Return from get_ValStatus - CAPE_NOT_VALIDATED This is not consistent with the logging of for example a call to get_Value: Parameter <Check> : Call to get_Value
Parameter <Check> : Return from get_Value - Succeeded I think the log of get_ValStatus should look like: Unit <CO1> : Call to get_ValStatus get_ValStatus returns CAPE_NOT_VALIDATED Unit <CO1> : Return from get_ValStatus - Succeeded |
|||
#39 | fixed | Argument of put_ComponentName call not displayed | Michael Halloran | michelpons |
Description |
I am using the material of Ticket#28. When examining the log obtained with COLTT 1.08.4, I find the following sequence: Unit <Anonymous> : Call to put_ComponentName Unit <Anonymous> : Return from put_ComponentName - Succeeded Unit <CO1> : Call to get_ports Unit <CO1> : Return from get_ports - Succeeded My belief is that \"CO1\" is the name that is put on the UO by the call to put_ComponentName so it would be fitting to have it appearing within the log of put_ComponentName such as in: Unit <Anonymous> : Call to put_ComponentName ComponentName: CO1 Unit <Anonymous> : Return from put_ComponentName - Succeeded |
|||
#40 | fixed | Error log from ResolvePropertyPackage | Michael Halloran | michelpons |
Description |
While making a test of a Simulis Thermo System Property Package in UniSim Design, I made a mistake entering the IP address of the Simulis license server. Then I got a run involving a Simulis PP in UniSim Design to go wrong while the PP was logged with COLTT. The log shows:
ClassFactory : Loading Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) implemented by
C:
ThermoSystem <Anonymous> : Return from GetPropertyPackages - Succeeded
ParameterCollection Parameter Collection Final Release...
Simulation Context <Anonymous> : Final Release
ThermoSystem <Anonymous> : Final Release
ClassFactory : Loading Simulis CAPE-OPEN® Thermo System (1.0) / P.P.M. (1.1) implemented by
C:
ThermoSystem <Anonymous> : Error returned from ResolvePropertyPackage - 0x8007000e ParameterCollection Parameter Collection Final Release... Simulation Context <Anonymous> : Final Release ThermoSystem <Anonymous> : Final Release To me it seems that there is no attempt by COLTT to retrieve info on the error. For sure the error code is not a CAPE-OPEN one still... |