Ticket Resolution Summary Owner Reporter
#85 worksforme Name of interface queried lacking in Viewer michaelhalloran michelpons

Reported by michelpons, 13 years ago.

Description

The loggers are able to log the fact that a query has been made about the presence of a CAPE-OPEN interface on a PMC. It appears in the log file as, for example: ThermoSystem <Anonymous> : Call to QueryInterface for ICapeUtilities ThermoSystem <Anonymous> : Return from QueryInterface for ICapeUtilities - Succeeded

But in the Viewer, if the query call does appear, there is no mention about which interface the call has been made. There may be the need to develop some more the reporting on this because the name of the interface queried is about as important as the fact that it was queried.

#86 worksforme Return from SetProp not logged michaelhalloran michelpons

Reported by michelpons, 13 years ago.

Description

I am using a Simulis Thermodynamics Property Package adhering to CAPE-OPEN 1.0 in UniSim Design. I am making a simple flash on a stream. UniSim Design is calling addtional property calculations in order to fill its properties display. Just after the last CalcEquilibrium call logged in the log file, UniSim Design requests a enthalpy calculation on the vapor phase. Simulis PP gets the compound IDs, overall temperature, overall pressure, vapor phase composition and then sets the enthalpy for vapor phase in the MO on a molar basis and then on a mass basis. In the log I don't see the last SetProp being returned. Still other calls are then logged. What can be going on? The Viewer lets this appear as an error. Is it one?

#88 worksforme COLTT does not recognize UO as supporting CAPE-OPEN interfaces michaelhalloran michelpons

Reported by michelpons, 13 years ago.

Description

I am using the case described in Ticket 03. I am using COLTT build dated July 17, 2011. This build incorporates a test about presence of Microsoft .Net 3.5 on the machine at installation. Since ProSim Plus does not need .Net 3.5 I installed .NET 3.5 SP1 and the necessary updates (except KB2518864 which did not succeed). The scenario calls for starting ProSim Plus with a case file that contains only four streams, one being the inlet. I insert the UO in the flowsheet and I connect its ports (one inlet, three outlets) to streams in the flowsheet. I define the UO parameters using the Edit function. Connection of ports, edition work fine from a ProSim Plus point of view with or without COLTT enabled on the UO. When asking for the UO to validate itself I get the kind of error message that is mentioned in Ticket 03. Now with COLTT build July 17, 2011, I get a very short log file saying that the UO is not supporting CO interfaces that COLTT may logged. I uninstalled COLTT July 17, 2011 and I installed the 1.08.04 version available from SourceForge. That time I get a rather complete log file that shows COLTT is able to log what happens between the PME and the PMC. Stating that the UO is not supporting the CO interfaces seems a little bit strange then.