#6 fixed InitNew call not logged michaelhalloran michelpons

Reported by michelpons, 15 years ago.

Description

A defect had been raised a while ago with SimSci-Esscor about the fact that InitNew was not called by PRO/II on a a new CAPE-OPEN UO being inserted in a flowsheet. According to SimSci-Esscor secondary support, the bug LFPE#25122 (InitNew not called) got fixed and working fine. However the log I can make of a COUSCOUS UO in PRO/II 8.3 does not show InitNew being called (see proii_090909_194007.log). SimSci-Esscor thinks that COLLT is not reporting InitNew call when the persistence type is IPersistPropertyBag.

They have tested the behavior with their internal CAPE-OPEN test units (COSESPersistB100.dll, COSESPersistC100.dll and COSESPersistD100.dll in zipped archive). The COLTT log file (proiid_PKM.log) shows that InitNew is called for persistence types IPersistStreamInit and IPersistStorage (they made their run with COLTT 1.07). However, the COLTT log file does not show the call to InitNew when the persistence type is IPersistPropertyBag. SimSci-Esscor has debugged the code and noticed that InitNew is called for IPersistPropertyBag also. So there is a good chance that COLTT has not implemented IPersistPropertyBag and that leads to an improper report on InitNew being called.

#7 fixed Call to ICapeUnit not supported in COLTT michaelhalloran michelpons

Reported by michelpons, 15 years ago.

Description

With a tailored-made CAPE-OPEN Unit Operation in PRO/II I get a crash that may be already documented as a bug. Still what is puzzling me is the following line in the log:

Unit <Anonymous> : Call to ICapeUnit not supported in COLTT

How can this be?

#8 fixed Aspen Properties initialization fails when logged Michael Halloran michelpons

Reported by michelpons, 15 years ago.

Description

I am conducting an interoperability test between an Aspen Properties Property Package and gPROMS. Aspen Properties is at version 7.1 CP1 and gPROMS at version 3.2.0, so they are at their current latest versions.

The test fails and COLTT is brought in to investigate. By using COLTT v1.07 on Aspen Properties Thermo System, I get a log file explaining what happens. With COLTT v1.08.02 enabled on Aspen Properties Thermo System, the run stops early on with initialization failing for the Thermo System.