#29 fixed Size of MSI ahsanakhtar michelpons

Reported by michelpons, 14 years ago.

Description

Size of the MSI file for COLTT 1.08.3 (Build Oct 27, 2009) is 22,178 Kbytes while it was only 4,646 Kbytes for the MSI of COLTT 1.07. Refactoring was not supposed to give way to such an increase in code size. So why such an increase?

#31 fixed 09-012 Version 0.93 UO michaelhalloran michelpons

Reported by michelpons, 14 years ago.

Description

De: Michel Pons [technologyofficer@…] Envoyé: Thursday, June 18, 2009 11:11 AM À: 'Ahsan Akhtar' Cc: 'michaeljhalloran@…' Objet: SimSci UO in PRO/II

Pièces jointes: MyScreenCopies.doc

Hi,

In the attached Word document I have documented a scenario that leads to a crash in PRO/II when either COLTT 1.07 or 1.08.02 is enabled on a UO. I think that the crash is related to the fact that the UO is 0.93 compliant. Could there be a way to avoid such a crash which does not look good?

I have listed this issue as 09-012.

Best regards

Michel

#32 fixed SetFontCellColor error Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

With COLTT 1.08.3 Build Oct 27, 2009 enabled on GLCC UO in Aspen Hysys, I get at first the same error messages as with GLCC UO alone (related to array parameters) but then I have a stream of error messages about SetFontCellColor error that I don't get with GLCC alone. I obtain a log file (hysys_110309_150132.log attached as zip) but the behavior is wrong. Attached is also screenshots of the scenario played (MyScreenshots031109.zip) in a RTF file.