Ticket Resolution Summary Owner Reporter
#25 fixed 08-023 Simulis Thermodynamics in COFE Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

The defect had been documented as issue 08-023. It involves COFE 1.14 and Simulis Thermodynamics 1.3.0.19. I have not updated the PMC and the PME to their latest versions. However I am using COLTT 1.08.3 as built on October 27, 2009.

In the zipped Word document, the issue had been already documented. When COLTT is enabled on Simulis PPM, one can't get the list of Property Packages supported by the PPM: COFE crashes. When COLTT is not enabled on Simulis PPM, the list of available PPs is displayed in COFE.

I have also attached the log file obtained, which is rather short.

#28 worksforme 08-136 COUSCOUS UO in PRO/II 8.2 Michael Halloran michelpons

Reported by michelpons, 14 years ago.

Description

I used COLTT 1.08.3 Build Oct 27, 2009 on a combination of PMC-PME that was used to document a defect in 2008 where it was impossible to get a log with COLTT 1.06. Logging is now possible with COLTT latest version.

The calculation does not run properly in PRO/II. This may be related to the fact that it is PRO/II 8.2 that is used here. I get an error message from PRO/II saying:

2 error(s), 0 warning(s), and 0 message(s) detected:

* error * Unit 1, 'co1' - the cape-open data file 'c:
docume~1
michel~1
locals~1
temp
ssi82
unconnected_co1.Dat' was not found. * error * Unit 1, 'co1' - not all material ports are connected.

The COLTT log file (proii_103109_232827.log) is showing that disconnect calls on ports are raising exceptions:

Port <Outlet> : Return from get_portType - Succeeded Port <Inlet 1> : Call to Disconnect Port <Inlet 1> : Error returned from Disconnect - 0x80040501 Port <Inlet 2> : Call to Disconnect Port <Inlet 2> : Error returned from Disconnect - 0x80040501 Port <Outlet> : Call to Disconnect Port <Outlet> : Error returned from Disconnect - 0x80040501

PRO/II seems to choose not to investigate further the exception since no attempt seems to be made to get information on the error. However I am puzzled by the fact that COLTT does not try either. I thought that, whatever the PME behaviour regarding error handling, COLTT logger was supposed to call ECapeUser and so on in order to get at least a better description of the error. It does not seem to happen there so the log is not sufficiently informative.

#11 fixed 09-001 richtx32 ocx file not properly registered at installation ahsanakhtar michelpons

Reported by michelpons, 14 years ago.

Description

I have installed COLTT 1.08.03 in a machine with UniSim Design and Simulis Thermodynamics. When launching COLTT controller I got a debug assertion failed message. UniSim Design being very close to Aspen Hysys, I figured the issue was with richtx32.ocx not properly registered at installation. Indeed using regsvr32 on richtx32.ocx resolved the issue that was supposed to have been resolved in 1.08.03.